IBO  - M1.8 ACS 4 Lobed Screw - INTHEX NP (3.5mm)  Titanium Screw - # IBO 1501 225
SKU: 483052 - In stock
Quantity:

Minimum quantity is 1.

Manufacturer #
IBO 1501 225
Manufacturer
Model
ZIMMER
Features
Fixation Screws
Package
1pk
In Stock
28

Description

IBO
Connections that Transform

ACS 4-Lobed Component — IBO 1501 225

Reference IBO 1501 225 · IBO ACS 4-Lobed prosthetic system
ACS 4-Lobed Component — IBO 1501 225 — product photo

DESCRIPTION

IBO ACS 4-Lobed prosthetic component, reference IBO 1501 225, M1.8 ACS 4 Lobed Screw 1501 225. The 4-Lobed drive interface provides enhanced rotational torque transfer and reduced cam-out compared to traditional hex drives in the prosthetic Screw application.

Reference: IBO 1501 225 · M1.8 ACS 4 Lobed Screw 1501 225.
Drive interface: 4-Lobed (ACS)IBO's anti-cam-out Screw drive system.
Thread size: per the M-designation in the product name (M1.4 / M1.6 / M1.8 / M2).
Application: prosthetic Screw or matched driver in IBO's ACS-compatible abutment lines.
Material: medical-grade Titanium alloy or Screw-grade Titanium variants for the Screw application.

CLINICAL APPLICATION

Used in IBO's ACS-compatible prosthetic workflows to fixate abutments to implant fixtures with controlled, repeatable torque. The 4-Lobed drive accepts the matched IBO ACS driver tip and reduces driver slippage during final torque application.

Apply final torque per IBO's loading specification for the matched abutment and implant.
Use only with the matched ACS 4-Lobed driver tip; standard hex drivers will not engage the 4-Lobed seat.
Single-use prosthetic screws are recommended; do not reuse a torqued Screw on a new abutment.

PLATFORM & COMPATIBILITY

The ACS 4-Lobed interface is used across IBO's Conical Reactive and INTHEX (Internal Hex) prosthetic lines where ACS-compatible screws are specified. Refer to the IBO instrument kit for the matched driver reference.

TECHNICAL SPECIFICATIONS

Manufacturer referenceIBO 1501 225
BrandIBO
Product familyACS 4-Lobed Component
DesignationM1.8 ACS 4 Lobed Screw 1501 225
Drive interface4-Lobed (anti-cam-out)
MaterialMedical-grade Titanium alloy
CompatibilityIBO ACS-compatible prosthetic screws and abutments
Package1pk
RegulatoryCE marking MDR · ISO 13485:2016 · AEMPS licence

MATERIALS & SURFACE

Machined from medical-grade Ti-6Al-4V ELI Titanium (Grade 5), ASTM F136 / ISO 5832-3, selected for biocompatibility, mechanical strength and chemical stability in the oral environment.

All materials and processes comply with current regulations and are subject to full traceability from raw material to final validation.

STERILIZATION & HANDLING

Supplied in the manufacturer's validated condition for clinical use. Follow the package insert and IBO Instructions for Use for handling, storage and any chairside preparation steps. Do not modify the geometry or surface in any way; doing so compromises both clinical fit and regulatory clearance.

Single-use device. Single patient, single procedure. Discard unused components per local biohazard regulations.

QUALITY ASSURANCE

IBO operates under ISO 13485:2016 quality management for the manufacturing of medical devices, holds the AEMPS Spanish Agency of Medicines and Medical Devices licence, and every IBO component carries the CE marking MDR, assessed by a Notified Body.

Material selection — alloys validated for biocompatibility and durability.
Dimensional verification — every batch inspected; functional sampling under fatigue and fracture testing.
Mechanical testing — ISO 14801:2016 fatigue and accelerated-ageing testing under cyclic loads representative of the oral environment.
Biocompatibility validation — cytotoxicity (ISO 10993-5:2009) and intracutaneous testing (ISO 10993-10:2021), following ISO 10993-1:2025 principles.
Service-life guaranteeIBO quality commitment ensures durability and performance across the device's service life.
Product description last updated: May 19, 2026

Attachments

Similar products